EFLOW USA, LLC 184 S. LIVINGSTON AVENUE STE 9107 LIVINGSTON, NJ 07039

8 Court Square, Long Island City, NY

8 Court Square building is nearly complete and features variety of eFlow-products for automatically balanced and controlled ventilation.

8 Court Square is a 20-story residential tower located at 27-10 44th Drive in Long Island City, NY. This 224-foot-tall structure will yield 107,377 square feet of residential space spread across 157 units, as well as 10,170 square feet for commercial space.

eFlow-CARs 4″ at 25 CFM were installed in every apartment exhaust. eFlow-CAR 6″ high pressure (0.6″w.c.-2.4″w.c.) at  125 CFM in wall mount fire damper assemblies were utilized for supply application. e2Flow PLUS system was installed to control on demand high airflow. e2Flow PLUS is exclusive to eFlow and it’s used as ZRT alternative solution.

8 Court Square was developed by 25-34 Jackson Avenue Property Owner LLC, designed by Hill West Architects and Cauldwell Wingate Company is the general contractor on record. Installation of eFlow-Products was undertaken by PI mechanical.

The manufacturers representative, SRS Enterprises, Inc,  facilitated the sale of eFlow products for this project.

8 Court Square is expected to be completed  in 2023.

 

Flow-CAR FACTS

eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.

  • UL 2043 Classified
  • Composed of fire resistant UL 94 ABS plastic
  • Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
  • Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
  • Airflow settings: 15-765 CFM
  • Temperature Limits: -22° to 140°F (-30° to 60°C)
  • Suitable for both supply and exhaust applications
  • No external power supply needed
  • Field Adjustable CFM set point
  • Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
  • Standard for Energy Efficient Compliance

 

Flow-CAR Fire Damper Assembly FACTS 

eFlow-CAR is inserted in a heavy-gauge galvanized steel enclosure that is designed to accommodate installation of fire damper and standard aluminum grille. eFlow-CAR is removable from the assembly to allow for easy CFM adjustment. Each enclosure is designed to specifically accommodate eFlow-CAR and expertly welded to prevent unwanted air leakage. The assembly is custom sized for each project.

Available Options:

● Supply Application
● Exhaust Application
● Back inlet
● Side inlet
● Top inlet
● UL rated 555, 1 ½ hours, thin line Fire damper
● Aluminum grille
● Retrofit Gasket

 

e2Flow® PLUS FACTS (ZRT Alternative Solution)

e2Flow® PLUS system is designed to introduce flexibility and demand control to central ventilation systems. It is used to achieve a combination of low-flow continuous indoor air quality ventilation and on-demand high-flow spot ventilation using the same central fan system. This high efficiency ventilation system promotes high indoor air quality, energy savings and reduces operating costs. This system is used in both large and small systems. Unlike any other product on the market, e2Flow® PLUS offers flexibility in engineering design where system’s components are tailored to the project’s requirements. Combination of two eFlow devices are used to achieve controlled minimum and maximum airflow. e2Flow® PLUS offers simple in-line installation where no mounting hardware or additional support is required. 

e2Flow® PLUS is ideal for bathroom, kitchen exhaust, makeup air, new constructions, retrofits and so much more. 

  • Achieve a combination of low-flow continues ventilation and on-demand high-flow spot ventilation
  • Mix & Match eFlow products for optimal solution
  • Easy in-line installation
  • No mounting hardware or additional support required
  • Low installation cost 
  • Refer to schematic for installation illustration   

 

Visit eflowshop.net for product information and pricing or email [email protected]

 

 

 

 

 

 

 

 

 

 

 

Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp

Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp

United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh

nailor constant volume regulator CVR-SP, CVR-LP, CVR-HP, CVR-T, CVR-GM, CVR-FD

eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F

 

Marble Hall Apartments, 100 Columbus Ave, Tuckahoe, NY

As part of $5.78 million updates, Marble Hall Apartments installed eFlow-Constant Airflow Regulators (CARs).

Located at 100 Columbus Avenue, Marble Hall is a ten-story affordable rental building which offers 133 units for those earning no more than 60 percent area median income, plus an employee unit for a total of 134 units.

LIHC Investment Group and Silver Street Development Corporation devoted $5.78 million to renovate the 50-year-old building and extend its useful life. Special attention was paid to improving the property’s energy efficiency which included installation of eFlow-CARs 4” at 40 CFM in every kitchen and bathroom exhaust, the replacement of heat and hot water boilers with energy-efficient units, Energy Star Qualified LED lighting.

Installation of eFlow-CAR was undertaken by Remediation Specialists Inc (RSI).

Flow-CAR FACTS

eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.

  • UL 2043 Classified
  • Composed of fire resistant UL 94 ABS plastic
  • Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
  • Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
  • Airflow settings: 15-765 CFM
  • Temperature Limits: -22° to 140°F (-30° to 60°C)
  • Suitable for both supply and exhaust applications
  • No external power supply needed
  • Field Adjustable CFM set point
  • Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
  • Standard for Energy Efficient Compliance

Visit eflowshop.net for product information and pricing or email [email protected]

 

 

 

 

 

 

 

 

 

 

 

 

 

Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp

Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp

United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh

nailor constant volume regulator CVR-SP, CVR-LP, CVR-HP, CVR-T, CVR-GM, CVR-FD

eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F

 

 

 

200 E. 17th Street, NYC

Another rental building located at 200 East 17th street in NYC features eFlow-Constant Airflow Regulators (CARs).

This 7 story, 56 apartment building was originally built in 1959. As part of a large retrofit project,  eFlow-CARs 4″ at 35 CFM  were installed in every apartment for automatically balanced ventilation, high indoor air quality and energy savings.

Installation of eFlow-CAR was undertaken by Remediation Specialists Inc (RSI).

Flow-CAR FACTS

eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.

  • UL 2043 Classified
  • Composed of fire resistant UL 94 ABS plastic
  • Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
  • Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
  • Airflow settings: 15-765 CFM
  • Temperature Limits: -22° to 140°F (-30° to 60°C)
  • Suitable for both supply and exhaust applications
  • No external power supply needed
  • Field Adjustable CFM set point
  • Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
  • Standard for Energy Efficient Compliance

 

Visit eflowshop.net for product information and pricing or email [email protected]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp

Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp

United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh

nailor constant volume regulator CVR-SP, CVR-LP, CVR-HP, CVR-T, CVR-GM, CVR-FD

eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F

 

 

 

 

 

335 E 111th Street, NYC

Another NYCHA affordable housing building located at 335 East 111th street in NYC features eFlow-Constant Airflow Regulators (CARs).

This 6 story, 66 apartment building was originally built in 1969. It got much needed repairs as part of New York Housing Authority’s Permanent Affordability Commitment Together (PACT) program. The improvements included new bathrooms, kitchens, replacements of heating systems and installation of eFlow-CARs 3″ at 25 CFM  in each apartment for automatically balanced ventilation, high indoor air quality and energy savings.

Installation of eFlow-CAR was undertaken by Indoor Air Quality Champs, Inc.

Flow-CAR FACTS

eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.

  • UL 2043 Classified
  • Composed of fire resistant UL 94 ABS plastic
  • Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
  • Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
  • Airflow settings: 15-765 CFM
  • Temperature Limits: -22° to 140°F (-30° to 60°C)
  • Suitable for both supply and exhaust applications
  • No external power supply needed
  • Field Adjustable CFM set point
  • Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
  • Standard for Energy Efficient Compliance

 

Visit eflowshop.net for product information and pricing or email [email protected]

 

 

 

 

 

 

 

 

 

 

Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp

Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp

United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh

nailor constant volume regulator CVR-SP, CVR-LP, CVR-HP, CVR-T, CVR-GM, CVR-FD

eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F

 

 

 

American Express , 200 Vesey Street, NYC

eFlow-Constant Airflow Regulator (CAR’s) were installed in parts of American Express headquarters building in order to combat unbalanced ventilation and bad odor concerns.

3″ CARs at 25 CFM were installed for controlled exhaust and 6″ CARs at 130 CFM were used for fresh air supply. Mounting plate transitions were utilized for both applications.

200 Vesey Street, also known as the American Express Tower, is one of four towers that comprise the Brookfield Place complex in the Financial District of Lower Manhattan in New York City. The building is an example of postmodern architecture, as designed by Cesar Pelli & Associates, and contains over 2.1 million square feet of rentable office area.

This building suffered sever damage by the falling debris when the World Trade Center towers collapsed on September 11, 2001. The building had to be closed for repairs from September 11, 2001 until May 2002 as a result of damage sustained in the terrorist attacks.

200 Vesey Street holds LEED Gold certificate.

WB Engineers is responsible for mechanical updates, including specification of constant airflow regulators (CAR’s) to address unbalanced ventilation concerns.

Installation of eFlow-CAR was undertaken by Cannon Mechanical.

Flow-CAR FACTS

eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.

  • UL 2043 Classified
  • Composed of fire resistant UL 94 ABS plastic
  • Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
  • Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
  • Airflow settings: 15-765 CFM
  • Temperature Limits: -22° to 140°F (-30° to 60°C)
  • Suitable for both supply and exhaust applications
  • No external power supply needed
  • Field Adjustable CFM set point
  • Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
  • Standard for Energy Efficient Compliance

 

Visit eflowshop.net for product information and pricing or email [email protected]

 

 

 

 

 

 

 

 

 

Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp

Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp

United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh

nailor constant volume regulator CVR-SP, CVR-LP, CVR-HP, CVR-T, CVR-GM, CVR-FD

eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F

 

 

 

 