eFlow- Constant Airflow Regulator (CAR) assemblies were installed at 2110 Amsterdam Avenue for automatically balanced ventilation, energy savings and high indoor air quality.
Built in 1910, 2110 Amsterdam Avenue is a five-story city-owned apartment building. Community activists demanded the site be used for affordable housing. The restoration project resulted in the creation of 28 units of affordable living.
The affordable housing lottery is now open for CLOTH Amsterdam.
CLOTH’S Housing Development Department is dedicated to preserving and developing the housing stock of the Washington Heights neighborhood for low-income families.
It is the goal of CLOTH’s Housing Development Department to improve the quality of life for all residents of Washington Heights. CLOTH’s housing and support programs aims to remove barriers between residents and the social services needed for low-income families.
Without CLOTH’s development and preservation projects, many tenants would face overcrowded living conditions. Unfortunately over crowded living conditions are customary for many Washington Heights low-income families. To create safe and affordable living spaces, tenants live in completely rehabilitated units, which are stocked with all new major building systems.
Installation of eFlow-CAR assemblies was undertaken by BAB Mechanical Service & Maintenance, Inc.
Flow-CAR FACTS
eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.
- UL 2043 Classified
- Composed of fire resistant UL 94 ABS plastic
- Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
- Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
- Airflow settings: 15-765 CFM
- Temperature Limits: -22° to 140°F (-30° to 60°C)
- Suitable for both supply and exhaust applications
- No external power supply needed
- Field Adjustable CFM set point
- Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
- Standard for Energy Efficient Compliance
Visit eflowshop.net for product information and pricing or email sales@eflowusa.net
Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp
Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp
United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh
nailor constant volume regulator CVR-SP, CVR-LP, CVR-HP, CVR-T, CVR-GM, CVR-FD
eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F