EFLOW USA, LLC 184 S. LIVINGSTON AVENUE STE 9107 LIVINGSTON, NJ 07039

Malcom Towers, Fort Lee, NJ

LIHC Investment Group secured $42.5M in Financing for Malcolm Towers  upgrades which includes the installation of eFlow-Constant Airflow Regulators.
eFlow-CAR 3″ adjustable 10-30 CFM setting was installed  in every bathroom and kitchen exhaust of this 16 story building.
Malcom Towers FACTS

Malcolm Towers, located at 475 St. in Fort Lee, NJ, is a 226-unit, age-restricted, subsidized Section 8 development located in a desirable residential neighborhood along Main Street in Fort Lee, approximately one mile from the George Washington Bridge. The Property, constructed in 1979, contains studio and one-bedroom apartments. Malcolm Towers residents also enjoy a large community room, library, game room and private outdoor space with tables and benches.

eFlow-CAR FACTS

eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.

  • UL 2043 Classified
  • Composed of fire resistant UL 94 ABS plastic
  • Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
  • Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
  • Airflow settings: 15-765 CFM
  • Temperature Limits: -22° to 140°F (-30° to 60°C)
  • Suitable for both supply and exhaust applications
  • No external power supply needed
  • Field Adjustable CFM set point
  • Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
  • Standard for Energy Efficient Compliance

 

Visit eflowshop.net for product information and pricing or email sales@eflowusa.net

 

 

 

 

 

 

 

 

 

 

 

 

Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp

Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp

United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh

eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F

 

 

Search for products

Back to Top
Product has been added to your cart