EFLOW USA, LLC 184 S. LIVINGSTON AVENUE STE 9107 LIVINGSTON, NJ 07039

Highgarden Tower, 11 Garden St, New Rochelle, NY

The Highgarden Tower will feature eFlow-CAR assemblies for automatically balanced ventilation system!

The Highgarden Tower, located at 11 Garden Street  is one of the most recent mixed-income developments on the rise in New Rochelle, NY. This 100 percent affordable, 19 story residential tower will yield 219 rental units ranging from studios to three-bedroom homes. A total of 77 units will be reserved for victims of domestic violence.

eFlow-CAR  4″ at 25/50 CFM in 6″x6″ wall mount assembly with thin-line fire dampers will be installed for every apartment bathroom and kitchen airflow exhaust. For airflow supply, eFlow-CAR 6″  in 8″x8″ wall mount assembly with thin-line fire damper will be utilized.  Installation of eFlow-CARs will automatically balance airflow, result in energy savings and high indoor air quality.

Highgarden Tower is developed by Georgica Green Ventures (GGV), designed by architect Stephen B. Jacobs Group.  Installation of eFlow-CARs was undertaken by Thermotech Mechanical.

The manufacturers representative, Mechanical Technologies LLC,  facilitated the sale of eFlow products for this project.

This project is expected to be completed in 2024.

 

Flow-CAR FACTS

eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.

  • UL 2043 Classified
  • Composed of fire resistant UL 94 ABS plastic
  • Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
  • Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
  • Airflow settings: 15-765 CFM
  • Temperature Limits: -22° to 140°F (-30° to 60°C)
  • Suitable for both supply and exhaust applications
  • No external power supply needed
  • Field Adjustable CFM set point
  • Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
  • Standard for Energy Efficient Compliance

 

Visit eflowshop.net for product information and pricing or email sales@eflowusa.net

 

 

 

 

 

 

 

Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp

Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp

United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh

nailor constant volume regulator CVR-SP, CVR-LP, CVR-HP, CVR-T, CVR-GM, CVR-FD

eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F

 

 

 

171 North 1st Street, Brooklyn, NY

eFlow-Constant Airflow Regulators installed at 171 North 1st Street, Brooklyn, NY.

The new seven-story building located in the heart of Williamsburg neighborhood offers 57 apartment units, with seventh-story penthouses and three townhouses among them, measuring an average of 842 square feet. All apartment exhausts feature eFlow-CAR 4″ for automatically balanced ventilation system. eFlow-CAR wall assemblies were installed for fresh air supply.

 

Developer Gemini Rosemont Development Services acquired the site for $18.2 million in April 2020 and teamed up with Broadway Construction Group for this project. Fogarty Finger Architects  is listed on permits as the architect of record. Ventrop ECG, PLLC provided MEP/sustainability services.

Completion is estimated for 2023.

 

The manufacturers representative, SRS Enterprises Inc,  facilitated the sale of eFlow products for this project.

Flow-CAR FACTS

eFlow-CAR is a simple solution to balancing ventilation systems. Constant Airflow Regulator is a device that automatically regulates airflows in ventilation systems to constant levels. The passive control element responds to duct pressure, and requires no electric sensors, pneumatic sensors or controls. eFlow-CARs promote high indoor air quality and energy savings.

  • UL 2043 Classified
  • Composed of fire resistant UL 94 ABS plastic
  • Diameters offered: 3”, 4″, 5”, 6”, 8″, 10″
  • Operating Pressure Range: 0.08 to 2.4 in w.g. (20-600Pa)
  • Airflow settings: 15-765 CFM
  • Temperature Limits: -22° to 140°F (-30° to 60°C)
  • Suitable for both supply and exhaust applications
  • No external power supply needed
  • Field Adjustable CFM set point
  • Capable of maintaining constant airflow within +- 5% for nominal airflow throughout the target operating pressure range of 0.08 to 2.4 in.
  • Standard for Energy Efficient Compliance

 

Visit eflowshop.net for product information and pricing or email sales@eflowusa.net

 

 

 

 

 

 

 

 

 

 

 

 

 

Supprier to American Aldes assemblies: ccar-ii, car-iia, ccar-ii-lp, car-ii-hp, car-fea-ii, car-fsa-ii, cer-s-ii, cer-r-ii, cer-lp-sii, cer-lp-r-ii, cer-s-iir, cer-lp-s-iir, cer-fea-ii, cer-fea-iir, cer-lp-fea-ii, cer-lp-fea-iir, csr-s-ii, csr-r-ii, csr-lp-s-ii, csr-lp-r-ii, csr-s-iir, csr-lp-s-iir, csr-fsa-ii, csr-fsa-iir, csr-lp-fsa-ii, csr-lp-fsa-iir, cerb-ws-ii, cerb-wb-ii, cerb-cs-ii, cerb-cfs-ii, cerb-cfb-ii, csrb-ws-ii, csrb-wb-ii, csrb-cs-ii, csrb-cfs-ii, csrb-cfb-ii, Constant Exhaust Registers, Constant Supply Registers, Constant Exhaust Register Box, Constant Supply Register Box, zone register terminals, zrt, zrt-s, zrt-fr, zrt-frs, zrt-w, zrt-ws, zrt-w-fr, zrt-w-frs, zrt-il, zrt-pdil, zrt-pdil-hp, zrt-3pdil, zrt-3pdil-hp, zrt-sdil, zrt-sdil-1-hp

Aldes, American Aldes, car ii, car iia, car ii lp, car ii hp, car fea ii, car fsa ii, cer s ii, cer r ii, cer lp sii, cer lp r ii, cer s iir, cer lp s iir, cer fea ii, cer fea iir, cer lp fea ii, cer lp fea iir, csr s ii, csr r ii, csr lp s ii, csr lp r ii, csr s iir, csr lp s iir, csr fsa ii, csr fsa iir, csr lp fsa ii, csr lp fsa iir, cerb ws ii, cerb wb ii, cerb cs ii, cerb cfs ii, cerb cfb ii, csrb ws ii, csrb wb ii, csrb cs ii, csrb cfs ii, csrb cfb ii, zrt s, zrt fr, zrt frs, zrt w, zrt ws, zrt w fr, zrt w frs, zrt il, zrt pdil, zrt pdil hp, zrt 3pdil, zrt 3pdil hp, zrt sdil, zrt sdil 1 hp

United enertech precision flow system crb-10-s, crb 10 s, crb-10-e, crb 10 e, crb-10-e-cd, crb 10 e cd, crb-10-s-cd, crb 10 s cd, crb-10-e-cd, crb 10 e cd, united enertech precision flow model cr, precision flow model cr-lp, precision flow model cr-hp, young regulator cvr constant volume regulator ,model cvrf5, model cvr8, cvp plus enh

nailor constant volume regulator CVR-SP, CVR-LP, CVR-HP, CVR-T, CVR-GM, CVR-FD

eFlow CAR can be used as equivalent to aldes CAR3, CAR3-s, CER3-S, CER3-R, CER3-S-F, CSR3-S, CSR3-R, CSR3-S-F, CEB3-WS, CEB3-WB, CEB3-CS, CEB3-CS-F, CSB3-WS, CSB3-WB, CSB3-CS, CSB3-CS-F

 

 

 

0

Search for products

Back to Top
Product has been added to your cart